Perfusion Pumps

Voltage & Language Options

Catalog No. VAC Hz Lang
043 605 000
043 605 001
043 605 002
043 605 005
043 605 006
043 605 007
043 605 008
043 605 009
043 605 010

115
230
230
230
100
100
230
230
115
60
50
50
50
50
60
50
60
60
Eng
Eng UK
French
Span
Eng
Eng
Italian
Eng
Span

Line voltage requirement is ±10% VAC. Language refers to face labels only.  Pumpheads can be rotated 90°clockwise (043 605 7XX) or counterclockwise (043 605 8XX) prior to shipping.

Display Accuracy (RPM)
±2% of reading or ±1 count, whichever is greater (without load).

Tubing Size Range-Silicone Rubber
Minimum3/16” ID x 1/16” wall
Maximum5/8” ID x 1/8” wall
Double1/8” - 1/4” ID x 1/16” wall,
non-continuous use only.

Tubing Size Range-PVC
Minimum1/4” ID x 1/16” wall
Maximum5/8” ID x 1/8” wall
Double 1/8” - 1/4” ID x 1/16” wall,
non-continuous use only.

Power Consumption
LOAD Usage
Maximum: 280 Watts
Normal: 150 Watts

Physical Characteristics
Length: 56 cm (22.1 in)
Width: 18 cm (7.1 in)
Height: 33 cm (13.0 in)
Weight: 26 kg (57 lbs)

Leakage Current
100/115 VAC12 μA rms maximum
230 VAC20 μA rms maximum

Occlusion
Adjustment0.018 mm (0.007 in) per detent

Standard Accessories
Tubing Inserts Catalog No.
3/16” to 3/8” ID with 043 205 001
1/16” to 3/32” wall
Buckberg 4:1 Plegia 043 206 004

Perfusion Pump Options
Tubing Inserts Catalog No.
Dbl. 1/4” x 3/32” 043 205 003
Dbl. 5/15” x 1/16” 043 205 000
Dbl. 1/4” x 1/16” 043 205 002
Buckberg 1:1 Plegia 043 206 001
Buckberg 2:1 Plegia 043 206 002
Buckberg 8:1 Plegia 043 206 008

Master /Slave Pump Cable
Catalog Number 043028000

Console Bases

Console Base Size Selection

Cat No. Width (cm/in.) Weight (kg/lb.) Size
043 625 03X
043 625 04X
043 625 05X
043 625 06X
043 625 07X
69/27
86/34
104/41
122/48
140/55
44/97
48/105
51/113
55/121
59/129
3 Pos
4 Pos
5 Pos
6 Pos
7 Pos

For all console sizes: Depth 69 cm/27 in. , Height 140 cm/55 inc.

Electrical Configurations

X
1
2
3
4
VAC
115
230
230
100
HZ
50/60
50/60
50/60
50/60
Typical Location
North America
United Kingdom
European Continent
Japan

Line voltage requirements is ±10% VAC

Circuit Breakers
14 Amp 100/115 VAC
10 Amp 230 VAC

Standard Accessories
Two IV poles/masts and one crossbar mast
One pushbar (can be located on either side)
Four locking casters and 20 cable clips
5-10 system electrical connectors
2-3 isolated accessory electrical connectors
Drip trays in between pumps
Two hand cranks
10 velcro strips

Console Base Options
Venous Line Occluding Clamp – Catalog Number 043 213 104; short cable for console bases of three positions or less. Catalog Number 043 213 105; long cable for console bases of
four positions or more. Maximum tubing size is 3/4” OD.
There is no minimum tubing size.

Computerized Perfusion Controller

Voltage & Language Options

Catalog No.
043 655 500
043 655 501
043 655 502
043 655 505
043 655 506
043 655 508
043 655 510
VAC
115
230
230
230
100
230
115
Hz
50/60
50/60
50/60
50/60
50/60
50/60
50/60
Lang
Eng
Eng
French
Span
Eng
Italian
Spanish


Line voltage requirements are ±10% VAC.

Timers - 3 Channels
Range: 00:00:00 to 99:59:59
(hours:minutes:seconds)
Acuracy: ±1% of elapsed time.

Power Consumption
80 watts maximum

Circuit Breakers
1.0 Amp at 100/115 VAC; 0.6 AMP at 230 VAC

Leakage Current
100/115 VAC20 μA rms maximum
230 VAC40 μA rms maximum

Computerized Perfusion Controller

(continud)

Temperature Monitors - 6 Channels
Display range: 0-50°C
Display resolution: 0.1°
Accuracy: ±1.0°C w/probe
Transducer compatibility:
YSI-400 and YSI-500 with calibration
Pressure Monitor - 2 Channels
Pressure Alarm range: -200 to +400 mmHg
Pressure limited range -210 to +450 mmHg
Accuracy ±8 mmHg w/transducer

Air Emboli Protection System (AEPS)
AEPS Open Reservoir Level Detection Sensitivity:
Within diameter of transducer (1 cm/0.4in.),
0-40 Hct. blood temerature 10-40°C

AEPS Bubble Detection Sensitivity
> 0.7 ml at flow rates < 6.5 lpm with
3/8” x 3/32” tubing (PVC only)
> 0.3 ml at flow rates <3.0 lpm with
1/4” x 3/32” tubing (PVC only)
Response time for pump control: <1 second
Arterial line tubing compatibility:
3/8” x 3/32” or 1/4” x 3/32” (PVC only)

Cardioplegia Delivery System Display Range
Last volume delivered - 0 to 9999 ml
Total volume delivered - 0 to 9999 ml
Time since last delivery - 0 to 99:59:59
(hours: minutes:seconds)
Accuracy: ±10% of desired volume

Physical Characteristics

Electronics Module
Depth: 53 cm (32 in); Width 18 cm (7.1 in)
Height” 31 cm (12 in); Weight 13.6 kg

Display Module
Depth 6 cm (2.4 in) w/out mount
Depth: 22 cm (8.7 in) w/out fixed mount
Width 34 cm (13.3 in); Height: 24 cm (9.3 in)
Weight: 4 kg (9 lbs) w/mount

Standard Accessories
Remote Control Cable - 10 ft (2 each)
Catalog Number 043 255 018
Disposable Pressure Transducer (2 ea)
Pressure Transducer Cable - 12 ft (2 ea)
Air Bubble Sensor and Cable
Catalog Number 600 005 100
Air Bubble Sensor Holder & Mount
Catalog Number 600 064 000
AEPS 10 ft Control Cable - CPC to Pump
Catalog Number 043 217 000
CPC Video Data Cable -10 ft
Catalog Number 043 255 017
CPC Display Control Cable - 10 ft
Catalog Number 043 218 000
Temperature Simulator Kit
Catalog Number 043 252 100
CPC Display Arm - 10 cm (4 in)
Catalog Number 043 255 016